Home / Pinayfreesexchat / An error occurred while updating the firmware

An error occurred while updating the firmware america chat sex t

An error occurred downloading i OS 9.” and, naturally you’re probably looking for a solution for that error message to get i OS 9 updated successfully on your i Phone, i Pad, or i Pod touch, right?Well there’s good news, this is a really easy error to resolve…Scroll down to find the file which matches your device, update to i Tunes 12.3, then use the IPSW for the update.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 078 046 Pre-fail Always - 41112 2 Throughput_Performance 0x0025 253 253 030 Pre-fail Offline - 33619968 3 Spin_Up_Time 0x0023 100 100 025 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 4448 5 Reallocated_Sector_Ct 0x0033 253 253 024 Pre-fail Always - 0 7 Seek_Error_Rate 0x002f 100 100 047 Pre-fail Always - 2140 8 Seek_Time_Performance 0x0025 253 253 019 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 089 089 000 Old_age Always - 5655 10 Spin_Retry_Count 0x0033 253 253 020 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0032 253 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 4319 180 Unused_Rsvd_Blk_Cnt_Tot 0x002f 100 100 098 Pre-fail Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 253 100 000 Old_age Always - 327680 184 End-to-End_Error 0x0033 253 253 097 Pre-fail Always - 0 185 Unknown_Attribute 0x0030 100 100 000 Old_age Offline - 2 186 Unknown_Attribute 0x0032 253 253 000 Old_age Always - 1441792 187 Reported_Uncorrect 0x0032 100 026 000 Old_age Always - 281470684365183 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 1 189 High_Fly_Writes 0x003a 253 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 067 050 045 Old_age Always - 33 (Min/Max 23/33) 191 G-Sense_Error_Rate 0x0032 253 098 000 Old_age Always - 16580617 192 Power-Off_Retract_Count 0x0032 096 096 000 Old_age Always - 71566404 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 35363 195 Hardware_ECC_Recovered 0x003a 253 253 000 Old_age Always - 20430 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 087 000 Old_age Always - 1 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 517 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd hh:mm: where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. Error 517 occurred at disk power-on lifetime: 5654 hours (235 days 14 hours) When the command that caused the error occurred, the device was active or idle.

SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Self-test execution status: ( 118) The previous self-test completed having the read element of the test failed. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 03 1d 2a 97 ec Error: UNC 3 sectors at LBA = 0x0c972a1d = 211233309 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 18 2a 97 ec 08 .010 READ DMA ea 00 00 00 00 00 a0 08 .973 FLUSH CACHE EXT 35 00 08 20 44 d6 e0 08 .973 WRITE DMA EXT ea 00 00 00 00 00 a0 08 .949 FLUSH CACHE EXT 35 00 38 e8 43 d6 e0 08 .949 WRITE DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining Life Time(hours) LBA_of_first_error # 1 Extended offline Completed: read failure 60% 5618 201724230 # 2 Short offline Completed without error 00% 5617 - # 3 Short offline Completed without error 00% 5617 - # 4 Extended offline Completed without error 00% 5600 - # 5 Short offline Completed: read failure 90% 5595 239457889 # 6 Short offline Completed: read failure 90% 5595 239457889 # 7 Short captive Completed without error 00% 5305 - # 8 Short captive Completed without error 00% 5301 - # 9 Short captive Completed without error 00% 5301 - #10 Short captive Completed without error 00% 5301 - #11 Short captive Completed: read failure 90% 5301 214242167 #12 Extended offline Completed: read failure 60% 4819 176075039 #13 Short offline Completed without error 00% 4819 - #14 Short offline Aborted by host 90% 214 - #15 Short offline Aborted by host 90% 214 - #16 Short offline Completed without error 00% 214 - #17 Short offline Completed without error 00% 214 - #18 Short offline Completed without error 00% 4 - #19 Short offline Completed without error 00% 3 - #20 Short offline Completed without error 00% 2 - #21 Short offline Completed without error 00% 1 - 4 of 5 failed self-tests are outdated by newer successful extended offline self-test # 4 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. Update: As landroni suggested, I ran short and extended self-tests using gsmartcontrol. Extended test got aborted at 40% because of errors. Extended self-test routine recommended polling time: ( 111) minutes. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 00 00 00 a0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ec 00 00 00 00 00 a0 08 .320 IDENTIFY DEVICE c8 00 80 80 28 97 ec 08 .939 READ DMA c8 00 80 20 2a 97 ec 08 .409 READ DMA c8 00 90 c0 5b e2 e5 08 .394 READ DMA ca 00 98 00 9b 98 ec 08 .393 WRITE DMA Error 516 occurred at disk power-on lifetime: 5654 hours (235 days 14 hours) When the command that caused the error occurred, the device was active or idle.

Total time to complete Offline data collection: ( 783) seconds. If Selective self-test is pending on power-up, resume after 0 minute delay. Here is the the paste from self-test logs: smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-51-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, START OF INFORMATION SECTION === Model Family: Fujitsu MJA BH Device Model: FUJITSU MJA2250BH G2 Serial Number: K94PT972B7RS LU WWN Device Id: 5 00000e 043bcbddd Firmware Version: 8919 User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3f Local Time is: Sun Feb 23 2014 IST SMART support is: Available - device has SMART capability. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 00 00 00 a0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ec 00 00 00 00 00 a0 08 .216 IDENTIFY DEVICE c8 00 40 40 28 97 ec 08 .822 READ DMA ef 10 02 00 00 00 a0 08 .821 SET FEATURES [Reserved for Serial ATA] ec 00 00 00 00 00 a0 08 .819 IDENTIFY DEVICE ef 03 45 00 00 00 a0 08 .819 SET FEATURES [Set transfer mode] Error 515 occurred at disk power-on lifetime: 5654 hours (235 days 14 hours) When the command that caused the error occurred, the device was active or idle.

Advanced users who are comfortable with firmware files can ignore the software update failed error message by downloading the appropriate firmware for their i Phone, i Pad, or i Pod touch model, and updating i OS 9 manually with the IPSW file.

You can find the i OS 9 IPSW file download links for i Phone, i Pad, and i Pod touch here.

314 comments

  1. Heading My machine has crashed couple of times this week. Ran smartmontools test and got this result === START OF INFORMATION SECTION === Model Family Fujitsu.

  2. Lumia handsets to get Windows 10 Mobile upgrade. Error code 1009 app store is an error of iTunes that iOS users face while Select the network service that you use.

  3. Are you looking for a guide to bypass iPhone error 3194 while restoring your iPhone or iPad? Check the solutions below and see how to fix error 3194 successfully.

  4. A firmware update. There were loaders floating around that could pass a firmware code to the After I rebooted I got a disk read error, several

  5. Since we are receiving inquiries on Trusted Platform Module TPM, we are offering this assistance on updating the TPM firmware and converting between TPM 1.2 and 2.0.

  6. How to Fix iTunes Error 3194 During iOS Update on Your iPhone, iPad or iPod Touch if you get itunes error 11, it mostly means there's something going file.

Leave a Reply

Your email address will not be published. Required fields are marked *

*